Assessment of bias errors caused by texture and sampling methods in diffraction-based steel phase measurements

评估衍射法测定钢相时,织构和取样方法引起的偏差误差

阅读:1

Abstract

Many advanced high-strength steels rely on a metastable austenite phase for improvements in strength and formability. To date, no method has demonstrated the ability to provide accurate austenite phase fraction measurements in textured steels. Several techniques have been proposed, such as averaging the intensity of several peaks and/or summation of intensity from several sample orientations. The series of numerical experiments performed in this work sought to quantify the effects of texture on the measurement of the austenite phase fraction, with an emphasis on techniques suitable for laboratory X-ray diffraction. Simulated diffraction profiles were created with the following variables: texture components for the ferrite and austenite phases, the sharpness of each of the texture components, the number of peaks used for averaging in the phase fraction calculation, and the sampling scheme used for sample orientation summation in the phase fraction calculation. The resulting phase fraction calculations showed that texture, the number of peak pairs and the sampling method have a drastic effect on phase fraction measurements, causing significant bias errors. Hexagonal grids produced minimal bias errors and demonstrated a robust method of measuring phase fractions in textured materials.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。