Peri-Intubation Adverse Events in the Critically Ill Child After Hematopoietic Cell Transplant

造血干细胞移植后危重患儿插管前后不良事件

阅读:1

Abstract

OBJECTIVES: Mechanically ventilated children post-hematopoietic cell transplant (HCT) have increased morbidity and mortality compared with other mechanically ventilated critically ill children. Tracheal intubation-associated adverse events (TIAEs) and peri-intubation hypoxemia universally portend worse outcomes. We investigated whether adverse peri-intubation associated events occur at increased frequency in patients with HCT compared with non-HCT oncologic or other PICU patients and therefore might contribute to increased mortality. DESIGN: Retrospective cohort between 2014 and 2019. SETTING: Single-center academic noncardiac PICU. PATIENTS: Critically ill children who underwent tracheal intubation (TI). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Data from the local airway management quality improvement databases and Virtual Pediatric Systems were merged. These data were supplemented with a retrospective chart review for HCT-related data, including HCT indication, transplant-related comorbidity status, and patient condition at the time of TI procedure. The primary outcome was defined as the composite of hemodynamic TIAE (hypo/hypertension, arrhythmia, cardiac arrest) and/or peri-intubation hypoxemia (oxygen saturation < 80%) events. One thousand nine hundred thirty-one encounters underwent TI, of which 92 (4.8%) were post-HCT, while 319 (16.5%) had history of malignancy without HCT, and 1,520 (78.7%) had neither HCT nor malignancy. Children post-HCT were older more often had respiratory failure as an indication for intubation, use of catecholamine infusions peri-intubation, and use of noninvasive ventilation prior to intubation. Hemodynamic TIAE or peri-intubation hypoxemia were not different across three groups (HCT 16%, non-HCT with malignancy 10%, other 15). After adjusting for age, difficult airway feature, provider type, device, apneic oxygenation use, and indication for intubation, we did not identify an association between HCT status and the adverse TI outcome (odds ratio, 1.32 for HCT status vs other; 95% CI, 0.72-2.41; p = 0.37). CONCLUSIONS: In this single-center study, we did not identify an association between HCT status and hemodynamic TIAE or peri-intubation hypoxemia during TI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。