Conversion hip arthroplasty for failed internal fixation of ipsilateral femoral neck and shaft fractures: a case report

同侧股骨颈和股骨干骨折内固定失败后行髋关节置换术:病例报告

阅读:1

Abstract

BACKGROUND: Ipsilateral femoral neck and hip fractures are uncommon high energy injuries. In the literature no single method of treatment has emerged as superior to the others. A recent publication has documented the successful application of the rendezvous technique using dual-implants for treating these injuries. However in some cases, this technique may fail and revision surgery is required. CASE PRESENTATION: A 67-year old man sustained ipsilateral fractures of his femur and femoral neck in a road traffic accident. His injuries were treated by a dual construct consisting of a retrograde femoral nail and dynamic hip screw. Three months after surgery the hip screw cut out of the femoral head necessitating revision to a total hip arthroplasty. Surgery was carried out using a single stage two part procedure on a standard operating table without having to reposition or redrape the patient. There were no postoperative complications and at 1 year from surgery the patient is satisfied with the result and has returned to work. CONCLUSION: Conversion hip arthroplasty in the presence of dual implants is a technically challenging and unpredictable procedure, with an increased risk of complications. Our surgical approach provides a framework for orthopedic surgeons to safely perform this complex procedure.