Direct comparison of choline PET/CT and MRI in the diagnosis of lymph node metastases in patients with prostate cancer

直接比较胆碱PET/CT和MRI在诊断前列腺癌患者淋巴结转移中的应用

阅读:1

Abstract

BACKGROUND: Lymph node detection in prostate cancer is challenging and critical to determine treatment policy. Choline PET/CT (positron emission tomography/computed tomography) and magnetic resonance imaging (MRI) have been used for the evaluation of lymph node metastasis in patients with prostate cancer for the past decade. However, only limited patients underwent direct comparison studies. PURPOSE: To evaluate the diagnostic performance of choline PET/CT compared with MRI imaging for detecting lymph node metastases in prostate cancer patients. MATERIAL AND METHODS: Relevant English-language articles published before February 2018 were searched in PubMed database, Embase database, and Cochrane Library databases search using the keywords: (Prostate Neoplasm OR Prostate Cancer OR prostate carcinoma) and (Lymph Node) and (PET/CT OR positron emission tomography/computed tomography) and (choline or 2-hydroxy-N,N,N-trimethylethanaminium) and (magnetic resonance imaging OR MRI). Articles were included that directly compare the diagnostic performance and clinical utility of choline PET/CT and MRI for detecting lymph node metastases in prostate cancer patients. Study quality was assessed with QUADAS criteria. Analyses were performed on a per patient and a per node basis. The pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive likelihood ratio (LR+), and negative likelihood ratio (LR-) were calculated using Meta-Disc 1.4 software. Summary receiver-operating characteristic (SROC) curves constructed. RESULTS: A total of 362 patients from 8 studies involving fulfilled the inclusion criteria. On patient-based analysis, the pooled sensitivity, specificity, and DOR with a 95% confidence interval (CI) for choline PET/CT imaging were 0.59 (95%CI, 0.50-0.67), 0.92 (95%CI, 0.87-0.96), 17.37 (95%CI, 4.42-68.33), and for MRI imaging, they were 0.52 (95%CI, 0.44-0.61), 0.87 (95%CI, 0.81-0.92), 6.05 (95%CI, 3.09-11.85), respectively. On node-based, the corresponding values for choline PET/CT imaging were 0.51 (95%CI, 0.46-0.57), 0.99 (95%CI, 0.98-0.99), 65.55 (95%CI, 23.55-182.45), and for MRI imaging, they were 0.39 (95%CI, 0.34-0.44), 0.97 (95%CI, 0.96-0.97), 15.86 (95%CI, 8.96-28.05), respectively. CONCLUSION: Choline PET/CT performed better than MRI imaging in evaluating the lymph nodes metastasis of prostate cancer patients and had the potential to be broadly applied in clinical practice.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。