Comparison of whole body bone mineral density measurements between dual energy X-ray absorptiometry and novel bioelectrical impedance analysis

双能X射线吸收法与新型生物电阻抗分析法测量全身骨矿物质密度的比较

阅读:1

Abstract

Bone mineral density (BMD) is a crucial indicator of osteoporosis. Bioelectrical impedance analysis (BIA) introduces a new method for assessing body composition, specifically BMD measurement. Compared with existing ultrasound and dual-energy X-ray absorptiometry for BMD screening and diagnosis, BIA has the advantages of safety, convenience and speed. However, the accuracy of BIA for BMD measurement needs to be explored. This study aimed to evaluate the accuracy of the novel BIA technique in conducting whole-body BMD assessments in the general population of Taiwan. Overall, 318 healthy adults in Taiwan (37.67 ± 19.44 years of age; 145 male and 173 female patients) were included. Whole-body BMD was measured via foot-to-foot BIA-StarBIA-201 (StarBIA Meditek Co. LTD, Taichung, Taiwan) and the dual-energy X-ray absorptiometry (DXA) Lunar Prodigy technology (GE Medical Systems, Madison, WI, USA). Linear regression analysis, Pearson's correlation coefficient, the Bland-Altman plot, and paired t tests were used. The whole-body BMDs measured by BIA and DXA were 1.139 ± 0.124 g/cm(2) and 1.202 ± 0.168 g/cm(2), respectively. The regression equation was y = 1.057x + 0.063. The Pearson correlation coefficient, mean difference, and limits of agreement were r = 0.737, - 0.053 g/cm(2), and - 0.290-0.165 g/cm(2), respectively. The regression equation was y = 1.057x + 0.063. The Pearson correlation coefficient, mean difference, and limits of agreement were r = 0.737 (p < 0.001), - 0.053 g/cm(2), and - 0.290-0.165 g/cm(2), respectively. Standing BIA was correlated with the DXA gold standard for estimating whole-body BMD in adults; however, its interchangeability remains limited. The potential bias in the measurement results of this study represents a current challenge with BIA compared with that of DXA, and there is still room for improvement. The convenient BIA method for measuring whole-body BMD may be useful in the application of primary screening and future development of BMD assessment methods. BIA is widely used to measure body composition, but its application to the measurement of BMD represents a novel technological breakthrough.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。