Retrospective evaluation of radiological and clinical outcomes after surgical treatment of proximal femoral fractures utilizing PFNA and PFNA augmented

回顾性评估采用PFNA和PFNA增强技术治疗股骨近端骨折后的放射学和临床结果

阅读:1

Abstract

INTRODUCTION: The primary aim of this study was to evaluate the clinical and radiological outcomes after surgical treatment of proximal femoral fractures utilizing the Proximal Femoral Nail Antirotation (PFNA), with the main focus on complications and reoperations. The secondary aim was to compare the outcomes of patients with and without cement augmentation of the cephalomedullary nails. MATERIALS AND METHODS: All patients with an acute proximal femoral fracture consequently treated with a PFNA between January 2011 and Dezember  2018 were evaluated. Clinical and radiological data were assessed for intra- and postoperative complications, including treatment failure. In addition, intra- and postoperative radiographs were used to determine the position of the implant, and any migration, via Tip-Apex-Distance (TAD) and the caput-collum-diaphyseal angle (CCD). The accuracy of the fracture reduction was rated according to Baumgaertners criteria. RESULTS: Two hundred sixty-four consecutive patients (mean age 78.8 ± 12.0; 73.1% female) were included. The predominant OTA/AO fracture classification was 31A1 (153 cases, 58.0%). The average duration of surgery was 63.1 ± 28.0 min and showed no significant differences between PFNA and PFNA with augmentation. The implant positioning was rated as good in 222 cases (84.1%). Two hundred sixty-three patients (99.6%) showed evidence of healing within the time frame of three months postoperatively, one case of delayed union healed after secondary dynamization. During the observational period, 18 patients (6.8%) required a total of 23 additional surgeries. Overall, a lower reoperation rate was observed following the use of the augmentation option (2/86 patients (2.3%) vs. 16/178 patients (9.0%), p = 0.04). In particular, there were no cases of cut-out or cut-through among patients who underwent augmentation as part of osteosynthesis. CONCLUSIONS: Overall reoperation rate after surgical treatment of proximal femoral fractures utilizing the Proximal Femoral Nail Antirotation (PFNA) was 6.8%, with 23 additional surgeries performed in 18 patients. The usage of the PFNA with augmentation showed equally good implant positioning, excellent healing rates and fewer postoperative complications compared to the PFNA implant alone with a similar overall duration of surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。