Change of temperature field around different drainage structures in cold region tunnel based on model testing

基于模型试验的寒区隧道不同排水结构周围温度场变化研究

阅读:1

Abstract

Improper layout of drainage structures and inadequate insulation measures in cold tunnels can result in varying degrees of frost formation during operation. This study focuses on the Hongtoushan highway tunnel as an example, where the distribution characteristics of the temperature field around the lower drainage structure under different arrangements are investigated through indoor model testing. The results indicate that there is a significant hysteresis phenomenon in temperature changes across the cross-section as the burial depth increases. With an increase in the burial depth of the surrounding rock, the hysteresis time of temperature changes gradually elongates. The temperature variation pattern can be approximated by a cubic polynomial. In the vertical section, as the tunnel depth increases, the temperature of the surrounding rock in the lower part of the tunnel gradually rises while the amplitude of temperature change diminishes. The temperature near the centerline is relatively lower compared to the sides, where the temperature gradually increases moving away from the centerline.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。