Application and Validation of Activity Monitors' Epoch Lengths and Placement Sites for Physical Activity Assessment in Exergaming

体感游戏中活动监测器时长和放置位置在身体活动评估中的应用与验证

阅读:1

Abstract

We assessed the agreement of two ActiGraph activity monitors (wGT3X vs. GT9X) placed at the hip and the wrist and determined an appropriate epoch length for physical activity levels in an exergaming setting. Forty-seven young adults played a 30-min exergame while wearing wGT3X and GT9X on both hip and wrist placement sites and a heart rate sensor below the chest. Intraclass correlation coefficient indicated that intermonitor agreement in steps and activity counts was excellent on the hip and good on the wrist. Bland-Altman plots indicated good intermonitor agreement in the steps and activity counts on both placement sites but a significant intermonitor difference was detected in steps on the wrist. Time spent in sedentary and physical activity intensity levels varied across six epoch lengths and depended on the placement sites, whereas time spent from a 1-s epoch of the hip-worn monitors most accurately matched the relative exercise intensity by heart rate. Hip placement site was associated with better step-counting accuracy for both activity monitors and more valid estimation of physical activity levels. A 1-s epoch was the most appropriate epoch length to detect short bursts of intense physical activity and may be the best choice for data processing and analysis in exergaming studies examining intermittent physical activities.