1726. A Random Forest Prediction Model Accurately Identifies Periods at Increased Risk for Positive Legionella Cultures in a Hospital Water Distribution System

1726. 随机森林预测模型能够准确识别医院供水系统中军团菌培养阳性风险增加的时期

阅读:1

Abstract

BACKGROUND: Hospitals devote considerable resources to water distribution system (WS) surveillance and remediation for Legionella in an effort to reduce risk of transmitting Legionnaires disease (LD). There are no models that accurately predict periods of greatest risk for Legionella culture positivity (cx +) within a WS. Our goal was to build and validate a model based on weather and water parameters that predicted Legionella cx+ in our hospital WS. METHODS: One liter water samples from fixtures at 2 campuses were cultured for Legionella on BCYE plates with cysteine as part of infection prevention protocols. Logistic regression (LR) and random forest (RF) models included daily hospital WS measurements and Pittsburgh FAA weather observation station data. Training and validation used 2014–2015 and 2016–2017 data, respectively. Models predicted a first +cx within 14 day windows. RESULTS: Cxs were defined as + by loop-day, if any cx from within a unique WS loop was + for Legionella on a given day. Of the 7,272 water samples, 5,304 were collected from 16 buildings on 2 campuses in which ≥1 cx + was obtained. A total of 1,262 WS loop-days were collected over 339 unique days from these buildings. Details on training and validation data sets appear in figure. Overall, water was Legionella cx + on 3% of loop-days. Models predicted positivity if risk was >6%. The LR model comprised of independent predictors of cx + had sensitivity/specificity of 44%/80% (AUC: 0.715; misclassification error: 0.21), and PPV/NPV of 9%/97% in the validation data set. The RF model comprised of the same predictors had sensitivity/specificity of 100%/98% (AUC: 1.0; misclassification error: 0.02), and PPV/NPV of 67%/100%. The most important RF variables in the validation data set were WS temperature and minimum pH over the 7 days prior to cx. CONCLUSION: An RF model using water and weather data was validated as an accurate predictor of new Legionella cx+ within a hospital WS. Most importantly, NPV for the model was 100%, meaning that no positive Legionella cxs were recovered during periods identified as low-risk. The RF model is a powerful tool for most efficiently directing resources to Legionella surveillance and LD prevention. DISCLOSURES: All authors: No reported disclosures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。