Comparative Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Radioimmunoassay in Determining Plasma Aldosterone Concentration and Plasma Renin Activity for Primary Aldosteronism Screening

液相色谱-串联质谱法与放射免疫分析法测定血浆醛固酮浓度和血浆肾素活性在原发性醛固酮增多症筛查中的比较分析

阅读:1

Abstract

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) accurately measures plasma aldosterone concentration (PAC), but its correlation with radioimmunoassay (RIA), equivalent RIA levels, and optimal cutoff for PAC and aldosterone-to-renin ratio (ARR) in primary aldosteronism (PA) screening have not been determined in a Korean population. Our study of 127 patients who underwent diagnostic testing for PA showed that the LC-MS/MS and RIA methods have good correlation, with a mean bias of 29.3% for PAC. An LC-MS/MS PAC level of 11.7 ng/dL was equivalent to an RIA PAC level of 15 ng/dL. Receiver operating characteristic curve analysis showed that an LC-MS/MS PAC level of 10.3 ng/dL and LC-MS/MS ARR level of 20.0 provided sensitivity of 73.1% with a specificity of 57.3% and sensitivity of 92.3% with a specificity of 14.7%, respectively. When the LC-MS/MS method is used for PA screening, an adjustment of cutoff values is necessary.