Comparison between a Novel Knee Arthrometer and Simultaneous Stress Radiography for the Diagnosis of Complete and Partial Acute Anterior Cruciate Ligament Tears

新型膝关节测量仪与同步应力X线摄影术在诊断完全性和部分性急性前交叉韧带撕裂中的比较

阅读:1

Abstract

OBJECTIVES: The type of ligamentous tear and the degree of knee laxity have important guiding significance for the diagnosis and management of anterior cruciate ligament (ACL) tears. Instrumental measurement is necessary for ACL tears since physical examination and magnetic resonance imaging (MRI) cannot provide an objective and quantitative assessment of knee laxity. This study aimed to compare the application of a novel knee arthrometer and simultaneous stress radiography in differentiating between complete and partial acute ACL tears, and further assess the correlation between the two measurements. METHODS: A total of 106 patients with complete acute ACL tears and 52 patients with partial acute ACL tears were included in the study. Preoperative arthrometry and simultaneous stress radiography were performed using the Ligs arthrometer at 90, 120, and 150 N to assess side-to-side difference (SSD) in anterior knee laxity. The optimal threshold was determined using the receiver operating characteristic (ROC) curve. The area under the ROC curve (AUC) was used to assess the diagnostic value of the measurement. Pearson's correlation coefficient was used to assess the correlation between the two measurements. RESULTS: The optimal differential SSD thresholds in the Ligs arthrometer were 2.7 mm at 90 N, 3.8 mm at 120 N, and 4.6 mm at 150 N. Similarly, the optimal differential SSD thresholds in simultaneous stress radiography were 3.8 mm at 90 N, 5.1 mm at 120 N, and 5.6 mm at 150 N. The AUC analysis revealed that the Ligs arthrometer was fairly informative at 90 N (AUC = 0.851), 120 N (AUC = 0.878), and 150 N (AUC = 0.884), and simultaneous stress radiography was highly informative at 90 N (AUC = 0.910), 120 N (AUC = 0.925), and 150 N (AUC = 0.948). Moreover, the AUC of the combined measurements was 0.914 at 90 N, 0.931 at 120 N, and 0.951 at 150 N. A significantly strong correlation was found between the two measurements at 90 N (r = 0.743, p < 0.001), 120 N (r = 0.802, p < 0.001), and 150 N (r = 0.823, p < 0.001). CONCLUSIONS: The Ligs arthrometer and simultaneous stress radiography proved to be valid diagnostic tools to differentiate between complete and partial acute ACL tears, with a strong correlation between the two measurements in SSD values. Compared with single instrumental measurement, the combination of the two measurements can further improve the diagnostic value in this regard.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。