Electrochemical Characterisation and Confirmation of Antioxidative Properties of Ivermectin in Biological Medium

伊维菌素在生物介质中的电化学表征及其抗氧化特性的验证

阅读:1

Abstract

Ivermectin (IVM) is a drug from the group of anthelmintics used in veterinary and human medicine. Recently, interest in IVM has increased as it has been used for the treatment of some malignant diseases, as well as viral infections caused by the Zika virus, HIV-1 and SARS-CoV-2. The electrochemical behaviour of IVM was investigated using cyclic (CV), differential pulse (DPV) and square wave voltammetry (SWV) at glassy carbon electrode (GCE). IVM showed independent oxidation and reduction processes. The effect of pH and scan rate indicated the irreversibility of all processes and confirmed the diffusion character of oxidation and reduction as an adsorption-controlled process. Mechanisms for IVM oxidation at the tetrahydrofuran ring and reduction of the 1,4-diene structure in the IVM molecule are proposed. The redox behaviour of IVM in a biological matrix (human serum pool) showed a pronounced antioxidant potential similar to that of Trolox during short incubation, whereas a prolonged stay among biomolecules and in the presence of an exogenous pro-oxidant (tert-butyl hydroperoxide, TBH) resulted in a loss of its antioxidant effect. The antioxidant potential of IVM was confirmed by voltametric methodology which is proposed for the first time.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。