Abstract

PURPOSE: Translocator protein (TSPO) positron emission tomography (PET) using (18)F-GE-180 shows high tumor-to-brain contrast in high-grade glioma (HGG), even in areas without magnetic resonance imaging (MRI) contrast enhancement. Until now, the benefit of (18)F-GE-180 PET in primary radiation therapy (RT) and reirradiation (reRT) treatment planning for patients with HGG has not been assessed. METHODS AND MATERIALS: The possible benefit of (18)F-GE-180 PET in RT and reRT planning was retrospectively evaluated through post hoc spatial correlations of PET-based biological tumor volumes (BTVs) with conventional MRI-based consensus gross tumor volumes (cGTVs). To find the ideal threshold for BTV definition in RT and reRT treatment planning, tumor-to-background activity thresholds of 1.6, 1.8, and 2.0 were applied. Spatial overlap of PET- and MRI-based tumor volumes was measured by the Sørensen-Dice coefficient (SDC) and the conformity index (CI). Additionally, the minimal margin to include the entire BTV into the expanded cGTV was determined. RESULTS: Thirty-five primary RT and 16 reRT cases were examined. BTV1.6, BTV1.8, and BTV2.0 were significantly larger than corresponding cGTV volumes in primary RT (median volumes: 67.4, 50.7, and 39.1, respectively, vs 22.6 cm(3); P < .001, P < .001, and P = .017, respectively; Wilcoxon test) and reRT cases (median volumes: 80.5, 55.0, and 41.6, respectively, vs 22.7 cm(3); P = .001, P = .005, and P = .144, respectively; Wilcoxon test). BTV1.6, BTV1.8, and BTV2.0 showed low but increasing conformity with cGTVs in the primary RT (SDC: 0.51, 0.55, and 0.58, respectively; CI: 0.35, 0.38, and 0.41, respectively) and reRT setting (SDC: 0.38, 0.40, and 0.40, respectively; CI: 0.24, 0.25, and 0.25, respectively). The minimal margin required to include the BTV within the cGTV was significantly smaller in the RT versus the reRT setting for thresholds 1.6 and 1.8 but not significantly different for threshold 2.0 (median margin: 16, 12, and 10, respectively, vs 21.5, 17.5, and 13 mm, respectively; P = .007, P = .031, and P = .093, respectively; Mann-Whitney U test). CONCLUSIONS: (18)F-GE-180 PET provides valuable information in RT treatment planning for patients with HGG. (18)F-GE-180-based BTVs with a threshold of 2.0 were most consistent in primary and reRT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。