Investigation of Radiation Exposure of Medical Staff During Lateral Fluoroscopy for Posterior Spinal Fusion Surgery

对后路脊柱融合手术侧位透视过程中医务人员辐射暴露情况的调查

阅读:1

Abstract

Background/Objectives: In spinal surgery, it is especially crucial to insert implants in the correct location. Intraoperative fluoroscopy is often necessary to safely perform spinal surgery because of serious complications that can occur if the screw deviates. However, the use of intraoperative fluoroscopy comes at the cost of radiation exposure to the surgeons and operating room staff. Therefore, it is desirable for spinal surgeons to understand the characteristics of radiation in order to minimize patient and medical staff exposure. This study aimed to create an aerial radiation dose distribution map for lateral fluoroscopy, a commonly used technique for posterior spinal fusion. Methods: A human body-equivalent phantom was placed in a prone position on the Jackson Table. The measurement method used was a lateral fluoroscopic evaluation, assuming posterior spinal fusion. Measurements were taken at three levels: 80 (gonadal), 100 (thoracoabdominal), and 150 cm (lens and thyroid). Results: The highest radiation doses were received by primary surgeons. The scrub nurse was the next most exposed. Conclusions: We developed an aerial dose distribution map for lateral fluoroscopy in posterior spinal fusion. Radiation exposure was the highest among primary surgeons.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。