Potential clinical feasibility of synthetic MRI in bladder tumors: a comparative study with conventional MRI

合成磁共振成像在膀胱肿瘤诊断中的潜在临床可行性:与常规磁共振成像的比较研究

阅读:1

Abstract

BACKGROUND: Synthetic magnetic resonance imaging (MRI) can provide quantitative information about inherent tissue properties and synthesize tailored contrast-weighted images simultaneously in a single scan. This study aimed to investigate the clinical feasibility of synthetic MRI in bladder tumors. METHODS: A total of 47 patients (37 males; mean age: 66±10 years old) with postoperative pathology-confirmed papillary urothelial neoplasms of the bladder were enrolled in this retrospective study. A 2-dimensional (2D) multi-dynamic multi-echo pulse sequence was performed for synthetic MRI at 3T. The overall image quality, lesion conspicuity, contrast resolution, resolution of subtle anatomic structures, motion artifact, blurring, and graininess of images were subjectively evaluated by 2 radiologists independently using a 5-point Likert scale for qualitative analysis. The signal intensity ratio (SIR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured for quantitative analysis. Linear weighted Kappa, Wilcoxon's signed-rank test, and the Mann-Whitney U-test were used for statistical analysis. RESULTS: The interobserver consistency was excellent (κ values: 0.607-1). Synthetic T1-weighted (syn-T1w) and synthetic T2-weighted (syn-T2w) images obtained scores of 4 in most subjective terms, which were relatively smaller than those of conventional images. The SIR and SNR of syn-T1w were significantly higher than those of con-T1w images (SIR 2.37±0.86 vs. 1.47±0.20, P<0.001; SNR 21.83±9.43 vs. 14.81±3.30, P<0.001). No difference was found in SIR between syn-T2w and conventional T2-weighted (con-T2w) images, whereas the SNR of the syn-T2w was significantly lower (8.79±4.06 vs. 26.49±6.80, P<0.001). Additionally, the CNR of synthetic images was significantly lower than that of conventional images (T1w 1.41±0.72 vs. 2.68±1.04; T2w 1.40±0.87 vs. 4.03±1.55, all P<0.001). CONCLUSIONS: Synthetic MRI generates morphologic magnetic resonance (MR) images with diagnostically acceptable image quality in bladder tumors, especially T1-weighted images with high image contrast of tumors relative to urine. Further technological improvements are needed for synthetic MRI to reduce noise. Combined with T1, T2, and proton density (PD) quantitative data, synthetic MRI has potential for clinical application in bladder tumors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。