Optimization of a method for collecting infant and toddler urine for non-target analysis using cotton pads and commercially available disposable diapers

利用棉垫和市售一次性尿布优化收集婴幼儿尿液进行非靶向分析的方法

阅读:1

Abstract

BACKGROUND: Urine is an abundant and useful medium for measuring biomarkers related to chemical exposures in infants and children. Identification of novel biomarkers is greatly enhanced with non-targeted analysis (NTA), a powerful methodology for broad chemical analysis of environmental and biological specimens. However, collecting urine in non-toilet trained children presents many challenges, and contamination from specimen collection can impact NTA results. OBJECTIVES: We optimized a caregiver-driven method for collecting urine from infants and children using cotton pads and commercially available disposable diapers for NTA and demonstrate its applicability to various children biomonitoring studies. METHODS: Experiments were first performed to evaluate the effects of processing method (i.e., centrifuge vs. syringe), storage temperature, and diaper brand on recovery of urine absorbed to cotton pads. Caregivers of 11 children (<2 years) used and retained diapers (with cotton pads) to collect their child's urine for 24 h. Specimens were analyzed via a NTA method implementing an exclusion list of ions related to contamination from collection materials. RESULTS: Centrifuging cotton pads through a small-pore membrane, compared to a manual syringe method, and storing diapers at 4 °C, compared to room temperature, resulted in larger volumes of recovered sample. This method was successfully implemented to recover urine from cotton pads collected in the field; between 5-9 diapers were collected per child in 24 h, and the total mean volume of urine recovered was 44.7 (range 26.7-71.1) mL. NTA yielded a list of compounds present in urine and/or stool that may hold promise as biomarkers of chemical exposures from a variety of sources. IMPACT STATEMENT: Infant and children urine is a valuable matrix for studies of the early life exposome, in that numerous biological markers of exposure and outcome can be derived from a single analysis. Depending on the nature of the exposure study, it may be the case that a simple collection method that can be facilitated by caregivers of young children is desirable, especially when time-integrated samples or large volumes of urine are needed. We describe the process for development and results of an optimized method for urine collection and analysis using commercially available diapers and non-target analysis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。