Application of the Left Ventricular Pressure-Strain Loop Technique in Monitoring Improvement Factors of Patients With Heart Failure Reduced Ejection Fraction

左心室压力-应变环技术在监测射血分数降低的心力衰竭患者改善因素中的应用

阅读:1

Abstract

The left ventricular pressure-strain loop (PSL) is a new technique based on ultrasound for noninvasive quantitative evaluation of global and local myocardial work (MW). This study is aimed at evaluating improvement factors of patients with heart failure (HF) reduced ejection fraction (HFrEF) using the PSL technique. A total of 88 patients with HF were enrolled in this study, which had ≤ 40% left ventricular ejection fraction (LVEF). The EchoPAC workstation was used to obtain the global longitudinal strain (GLS) and MW parameters of the left ventricle. All patients have taken medicines for HF treatments for 6-12 months. The improvements of HF after therapies were evaluated according to the following recommended criteria. The clinical characteristics of patients with improved and nonimproved groups were stratified via univariate or multivariate logistic regression analysis, receiver operating characteristic (ROC), and the area under ROC (area under the curve (AUC)). There were no significant differences in general medical information, the underlying diseases, laboratory findings, myocardial enzyme activities, and taking medicines between the improved and nonimproved LVEF patients (p > 0.05). There were significant differences in LVEF of patients at admission, left ventricular end-diastolic diameter (LVEDD), interventricular septum thickness (IVST), early diastolic mitral flow peak velocity E (E peak), GLS, global myocardial work index (GWI), global myocardial constructive work (GCW), and global myocardial work efficiency (GWE) between the two groups (p < 0.05). Univariate and multivariate logistic regression analyses confirmed that GWI and GCW were critical predictive factors for LVEF improvement in patients with HF. ROC curve showed that the AUC of GWI and GCW were 0.796 and 0.779 at the cut-off of 741 mmHg% for GWI and 973.5 mmHg% for GCW, respectively. The sensitivities of GWI and GCW were 65% and 75%, and the specificities of GWI and GCW were 83.3% and 79.2% at given cut-off values. These results revealed that GWI and GCW were independent predictors of improvement of LVEF in patients with HFrEF.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。