Patient-specific optimization of mechanical ventilation for patients with acute respiratory distress syndrome using quasi-static pulmonary P-V data

利用准静态肺压力容积数据对急性呼吸窘迫综合征患者的机械通气进行个体化优化

阅读:1

Abstract

Quasi-static, pulmonary pressure-volume (P-V) curves were combined with a respiratory system model to analyze tidal pressure cycles, simulating mechanical ventilation of patients with acute respiratory distress syndrome (ARDS). Two important quantities including 1) tidal recruited volume and 2) tidal hyperinflated volume were analytically computed by integrating the distribution of alveolar elements over the affected pop-open pressure range. We analytically predicted the tidal recruited volume of four canine subjects and compared our results with similar experimental measurements on canine models for the validation. We then applied our mathematical model to the P-V data of ARDS populations in four stages of Early ARDS, Deep Knee, Advanced ARDS and Baby Lung to quantify the tidal recruited volume and tidal hyperinflated volume as an indicator of ventilator-induced lung injury (VILI). These quantitative predictions based on patient-specific P-V data suggest that the optimum parameters of mechanical ventilation including PEEP and Tidal Pressure (Volume) are largely varying among ARDS population and are primarily influenced by the degree in the severity of ARDS.