Near-Surface Dose Correlates With Moist Desquamation and Unplanned Reconstructive Surgery in Patients With Implant-Based Reconstruction Receiving Postmastectomy Radiation Therapy

乳房切除术后接受放射治疗的植入式乳房重建患者的近表面剂量与湿性脱屑和非计划性重建手术相关

阅读:1

Abstract

PURPOSE: Postmastectomy radiation therapy (PMRT) reduces disease recurrence in appropriately selected patients but may compromise implant-based reconstruction. We investigated whether near-surface dose correlates with radiation-related toxic effects in these patients. METHODS AND MATERIALS: Patients receiving PMRT at a single institution from 2016 to 2019 were retrospectively reviewed. Patient demographics and treatment information were collected. Three near-surface structures were retrospectively generated, bound by the chest wall tangent beam as well as the skin surface and the skin-3 mm contour (SR3), skin surface and skin-5 mm contour (SR5), or skin-5 and skin-10 mm contours. Dosimetric analysis of these near-surface contours was performed in 2 Gy intervals. Univariate and multivariate analyses were used to identify predictors of moist desquamation, grade 2+ chest wall pain, use of opiate pain medication, unplanned reconstructive surgery, and implant failure. Logistic regression for each outcome and near-surface contour was performed for receiver-operator area under the curve (AUC) analysis and the Youden J Statistic was used to determine the optimal threshold for each dosimetric parameter. RESULTS: Of 126 patients reviewed, 109 met the study's eligibility criteria. Median follow-up was 2.3 years. Twenty-five patients (23%) underwent unplanned reconstructive surgery, and 10 (9.2%) experienced implant failure. Among clinical variables, low body mass index and history of smoking predicted unplanned surgery on univariate and multivariate analyses, and moist desquamation predicted grade 2+ chest wall pain. The top dosimetric parameters by AUC for moist desquamation, grade 2+ chest wall pain, use of opiates, unplanned reconstructive surgery, and implant failure were SR5 D10 cc (AUC = 0.701, optimal threshold 57.8 Gy, P < .001), SR3 D10 cc (AUC = 0.600, optimal threshold 56.8 Gy, P = .079), SR5 D10 cc (AUC = 0.642, optimal threshold 57.3 Gy, P = .041), SR3 V44 Gy (AUC = 0.711, optimal threshold 81%, P = .001), and SR3 V44 Gy (AUC = 0.688, optimal threshold 82%, P = .052), respectively. CONCLUSIONS: Near-surface dose correlates with moist desquamation and unplanned reconstructive surgery after PMRT. Further evaluation of prospective optimization of dosimetric parameters related to SR3 and SR5 should be considered.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。