Ferritin: A Biomarker Requiring Caution in Clinical Decision

铁蛋白:临床决策中需谨慎使用的生物标志物

阅读:1

Abstract

OBJECTIVES: To determine the ferritin inter-assay differences between three "Conformité Européenne" (CE) marked tests, the impact on reference intervals (RI), and the proportion of individuals with iron deficiency (ID), we used plasma and serum from healthy blood donors (HBD) recruited in three different Switzerland regions. DESIGN AND METHODS: Heparinized plasma and serum from HBD were obtained from three different transfusion centers in Switzerland (Fribourg, Geneva, and Neuchatel). One hundred forty samples were recruited per center and per matrix, with a gender ratio of 50%, for a total of 420 HBD samples available per matrix. On both matrices, ferritin concentrations were quantified by three different laboratories using electrochemiluminescence (ECL), latex immunoturbidimetric assay (LIA), and luminescent oxygen channeling immunoassay (LOCI) assays, respectively. The degree of agreement between matrices and between the three sites/methods was assessed by Passing-Bablok and we evaluated the proportion of individuals deemed to have ID per method. RESULTS: Overall, no difference between serum and heparinized plasma ferritin values was observed according to Passing-Bablok analyses (proportional bias range: 1.0-3.0%; maximum constant bias: 1.84 µg/L). Significant median ferritin differences (p < 0.001 according to Kruskal-Wallis test) were observed between the three methods (i.e., 83.6 µg/L, 103.5 µg/L, and 62.1 µg/L for ECL, LIA, and LOCI in heparinized plasma, respectively), with proportional bias varying significantly between ±16% and ±32% on serum and from ±14% to ±35% on plasma with no sign of gender-related differences. Affecting the lower end of RI, the proportion of ID per method substantially varied between 4.76% (20/420) for ECL, 2.86% (12/420) for LIA, and 9.05% (38/420) for LOCI. CONCLUSIONS: Serum and heparinized plasma are exchangeable for ferritin assessment. However, the order of magnitude of ferritin differences across methods and HBD recruitment sites could lead to diagnostic errors if uniform RI were considered. Challenging the recently proposed use of uniform ferritin thresholds, our results highlight the importance of method- and region-specific RI for ferritin due to insufficient inter-assay harmonization. Failing to do so significantly impacts ID diagnosis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。