Refractory hypoxia and saturation gap in a COVID-19 patient

新冠肺炎患者的难治性低氧血症和饱和度差距

阅读:1

Abstract

Acquired methemoglobinemia, predominantly due to oxidizing medications occurs when heme iron in hemoglobin is oxidized from ferrous to ferric ion and binds oxygen irreversibly leading to functional anemia, cyanosis, and tissue hypoxia. We report a case of a 60-year-old man with multiple comorbidities who was diagnosed with coronavirus disease 2019 (COVID-19) and developed methemoglobinemia after consumption of prescribed supplements. He presented with dyspnea and cyanosis. An oxygen saturation gap with characteristic chocolate-brown arterial blood indicated methemoglobinemia. Outsourced methemoglobin (MetHb) was increased at 9.0%. Despite aggressive intervention, he succumbed to his illness. In this case, we discuss the pathophysiology of why some individuals, especially the elderly with COVID-19 are more susceptible to develop methemoglobinemia after possibly being exposed to oxidizing agents. Laboratory methods for assessing oxygen saturation, including pulse oximetry, arterial blood gas and co-oximetry are examined in relation to this case. The importance of considering a diagnosis of methemoglobinemia based on clinical and biochemical findings although MetHb assay or co-oximetry are not readily available is also emphasized.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。