Valuable Predictors for Non-measurability of Fractional Flow Reserve Derived From Coronary Computed Tomography Angiography

冠状动脉计算机断层扫描血管造影衍生的血流储备分数不可测量性的有价值的预测因子

阅读:1

Abstract

Background The fractional flow reserve (FFR) derived from coronary computed tomography (CT) angiography (FFRCT) is a variable tool for coronary disease diagnosis that non-invasively provides the value of FFR. It can add physiological information to coronary CT angiography (CCTA) and reduce unnecessary invasive coronary angiography (CAG). However, it cannot be analyzed in some cases, which is also called "non-measurability." While FFRCT has become globally widespread, the current data on non-measurability are lacking. This study aimed to determine the rate of non-measurability and identify predictors thereof in routine clinical settings to explore potential approaches to reduce the non-measurability rate. Methods and results This retrospective observational single-center study included consecutive patients who underwent FFRCTanalysis in Japan. The mean age of the overall population was 71.3 ± 10.6, and an FFRCTof ≤0.8 was seen in 47.6% of patients with a measurable FFRCT. Of the 307 enrolled patients, FFRCT analysis was not feasible in 21 cases (6.8%). Heart rate (HR) at a CT scan and coronary calcium scores (CCS) were significantly higher in patients with non-measurability than those in patients whose FFRCT was appropriately analyzed (HR: 69.6±8.9 bpm vs. 61.0±11.1 bpm; p < 0.01; CCS; 931.2 (290.8, 1451.3) vs. 322.9 (100.7, 850.0); p < 0.01). Multiple logistic regression showed that HR was an independent predictor for non-measurability (odds ratio: 1.05; 95% confidential interval: 1.02, 1.09; p < 0.01)). Based on the receiver operating characteristic curve analysis, the optimal cut-off value of HR and CCS was 63 bpm (specificity: 67.1%; sensitivity: 76.2%) and 729.2 (specificity: 71.3%; sensitivity: 66.7%). In addition, the combination of two features (HR > 63 bpm and CCS > 729.2) showed a high negative predictive value (99.3%) for FFRCT non-measurability. Conclusions In this study, the rate of FFRCTnon-measurability was 6.8%. Higher HR at a CT scan and CCS were significantly associated with non-measurability, and in cases with both HR and CCS below a specified threshold, the likelihood of ruling out non-measurability could be significantly high. Our findings suggest that reducing the HR to ideally under 63 bpm at the time of the CT scan significantly ensures feasibility. Further study on large-scale cohorts is warranted.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。