Temperature-tolerant COLD-PCR reduces temperature stringency and enables robust mutation enrichment

耐高温 COLD-PCR 降低了温度严格性并实现了稳健的突变富集

阅读:5
作者:E Castellanos-Rizaldos, Pingfang Liu, Coren A Milbury, Minakshi Guha, Angela Brisci, Laura Cremonesi, Maurizio Ferrari, Harvey Mamon, G Mike Makrigiorgos

Background

Low-level mutations in clinical tumor samples often reside below mutation detection limits, thus leading to false negatives that may impact clinical diagnosis and patient management. COLD-PCR (coamplification at lower denaturation temperature PCR) is a technology that magnifies unknown mutations during PCR, thus enabling downstream mutation detection. However, a practical difficulty in applying COLD-PCR has been the requirement for strict control of the denaturation temperature for a given sequence, to within ±0.3 °C. This requirement precludes simultaneous mutation enrichment in sequences of substantially different melting temperature (T(m)) and limits the technique to a single sequence at a time. We present a temperature-tolerant (TT) approach (TT-COLD-PCR) that reduces this obstacle.

Conclusions

Low-level mutations in diverse amplicons with different T(m)s can be mutation enriched via TT-COLD-PCR provided that their T(m)s fall within the denaturation-temperature window applied during amplification. This approach enables simultaneous enrichment of mutations in several amplicons and increases significantly the versatility of COLD-PCR.

Methods

We describe thermocycling programs featuring a gradual increase of the denaturation temperature during COLD-PCR. This approach enabled enrichment of mutations when the cycling achieves the appropriate critical denaturation temperature of each DNA amplicon that is being amplified. Validation was provided for KRAS (v-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog) and TP53 (tumor protein p53) exons 6-9 by use of dilutions of mutated DNA, clinical cancer samples, and plasma-circulating DNA.

Results

A single thermocycling program with a denaturation-temperature window of 2.5-3.0 °C enriches mutations in all DNA amplicons simultaneously, despite their different T(m)s. Mutation enrichments of 6-9-fold were obtained with TT-full-COLD-PCR. Higher mutation enrichments were obtained for the other 2 forms of COLD-PCR, fast-COLD-PCR, and ice-COLD-PCR. Conclusions: Low-level mutations in diverse amplicons with different T(m)s can be mutation enriched via TT-COLD-PCR provided that their T(m)s fall within the denaturation-temperature window applied during amplification. This approach enables simultaneous enrichment of mutations in several amplicons and increases significantly the versatility of COLD-PCR.