Efficacy comparison between iliosacral screw fixation of the posterior pelvic ring fracture with the assistance of modified percutaneous three-dimensional printing guide template and conventional fluoroscopy

改良经皮三维打印导板辅助下髂骶螺钉固定治疗后骨盆环骨折与传统透视下髂骶螺钉固定的疗效比较

阅读:1

Abstract

OBJECTIVES: The effect of three-dimensional (3D) printed bone-attached guide plate assisted cannulated screw fixation of pelvic fracture is reliable, but extensive soft tissue dissection is still required when installing the guide plate. This study aims to compare the efficacy of posterior pelvic ring fracture fixation with iliosacral screw insertion between the assistance of modified percutaneous patient specific 3D printed guide template and conventional fluoroscopy. METHODS: From May, 2019 and September 2021, 28 patients sustained posterior pelvic ring fractures were randomized into 2 groups: A guide template group, in which the iliosacral screw was inserted for fixation of the posterior pelvic ring fracture with the assistance of modified percutaneous patient specific 3D printed guide template, and a fluoroscopy group, in which the iliosacral screw was inserted under the guidance of conventional fluoroscopy. The operation time, fluoroscopic frequency, intraoperative blood loss, and incision length were recorded for each screw insertion. Fracture reduction was evaluated according to the Matta criteria. The screw position was evaluated according to the modified Gras classification, and the functional outcome was evaluated according to Majeed score. The parameters of both groups were compared, and statistical analysis was performed. RESULTS: All the 28 patients were followed up for 12-24 months. Of them, 15 iliosacral screws were inserted in 14 patients in the guide template group, and 14 iliosacral screws were inserted in 14 patients in the fluoroscopy group. The operation time, fluoroscopic frequency, screw deviation, incision length, and blood loss in the guide template group were 20-30(25.8±2.8) min, 9-15(12.2±1.9), 2-4(2.6±0.7) mm, 4-5(4.6±0.5) cm, and 5-10 (7.8±1.7) mL, respectively, whereas those in the fluoroscopy group were 30-60(48.1±7.5) min, 40-96(64.7±16.3), 3-6(4.2±0.9) mm, 0.8-1.2(1.0±0.1) cm, and 2-5(3.1±1.3) mL, respectively, and there were statistical significance (all P<0.001). Fracture reduction was evaluated according to the Matta criteria, and all the patients reached excellence and good (P=0.584) in the 2 groups. According to modified Gras classification, there were 12 Grade I screws, 3 Grade II screws, and 0 Grade III screws in the guide template group, and 10 Grade I screws, 3 Grade II screws, and 1 Grade III screw in the fluoroscopy group, with no statistical significance (P=0.334). The functional outcome was evaluated according to Majeed score at the last follow-up, without significant difference between the guide template group and the fluoroscopy group (P=0.908). CONCLUSIONS: Compared with the conventional fluoroscopy, it would cost less operation time, less fluoroscopic frequency and increase more accurate screw insertion to fixate the posterior pelvic ring fracture with the assistance of modified percutaneous patient specific 3D printed guide template.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。