Feasibility and tolerability of breath-hold in liver stereotactic body radiotherapy with surface guided radiotherapy

肝脏立体定向放射治疗联合表面引导放射治疗中屏气的可行性和耐受性

阅读:1

Abstract

PURPOSE: Intrafractional motion constitutes a significant challenge in SBRT (Stereotactic Body Radiotherapy).The breath-hold (BH) technique is employed to mitigate tumor motion; however, ensuring reproducibility and consistency remains critically important. Surface tracking systems, integrated into the treatment process, facilitate motion tracking through three-dimensional camera technology. Surface guidance has been incorporated with Varian EDGE (Varian Medical Systems, Palo Alto, CA, USA) and has been utilized at multiple treatment sites within our department since 2018. Drawing on four years of experience, this study aims to publish patient experience, assess the feasibility, and evaluate the tolerability of breath-hold during SBRT with surface guided radiotherapy (SGRT), particularly focusing on a specific subgroup: patients with liver metastases. METHODS: Prospective evaluation was conducted on patients with liver metastases undergoing breath-hold SBRT with SGRT. A two-step survey consisting of seven questions was administered after CT simulation and treatment. Treatment duration and the number of breath-holds were recorded. Additionally, factors potentially influencing SGRT and treatment time were assessed. RESULTS: Between April 2021 and May 2022, a total of 41 patients underwent 171 fractions of treatment. According to the questionnaire, prior training was found to be beneficial, and breath-holding during the procedure was tolerable. Patients reported experiencing slight stress due to their active participation in the treatment. Factors such as Karnofsky Performance Status (KPS), age, lung volume, conditions affecting lung capacity, previous breath-hold history, and being a native speaker showed no correlation with treatment time. Moreover, these factors did not correlate with the tolerability of breath-hold during SGRT. However, female patients showed better breath-holding performance in SGRT treatments compared to male patients (p: 0.02). CONCLUSIONS: The application of breath-hold with SGRT procedures is tolerable and feasible in liver SBRT treatments. There exists no specific subgroup that cannot tolerate this method.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。