Fluid Responsiveness in Critically Ill Patients Using Carotid Peak Systolic Velocity Variability: A New Frontier

利用颈动脉峰值收缩期速度变异性评估危重患者的液体反应性:一项新的研究

阅读:1

Abstract

Background and objectives A fluid responder is a patient who can increase his stroke volume/ cardiac output by more than 10%-15% after a fluid bolus. Left ventricular outflow tract (LVOT) velocity time integral (VTI) variability is widely used as an adynamic parameter of fluid responsiveness, but a transthoracic echo view of LVOT VTI is often time-consuming and, at times, difficult to achieve. So, in the quest for another parameter that might equally be a good surrogate marker of stroke volume variation, carotid peak systolic velocity (CPSV) variation has been studied. The objective was to assess CPSV variation in patients who are already fluid responders. Methods The sample size was calculated considering a minimum correlation coefficient of 0.5. Adult patients in whom the physician wanted to give a fluid bolus and whose average LVOT VTI was more than 15% over 3 respiratory cycles were included in the study. Demographic variables, along with hemodynamic parameters such as heart rate, blood pressure, the need for vasopressors, mode of breathing (spontaneous or mechanical ventilation), and CPSV variation,were noted and averaged over three respiratory cycles. Fluid bolus (Plasmalyte) 6 ml/kg bolus over 10-15 minutes. Post-fluid hemodynamic variables, along with averaged LVOT VTI over three respiratory cycles and averaged CPSV variation over three respiratory cycles, are noted. Results Thirty adult patients were evaluated in the study. In spontaneously breathing patients (n=12), the average CPSV variation expressed as mean + standard deviation before and after fluid administration of 6ml/kg of ideal body weight was 14.1 ± 3.4 and 5.4 ± 2.6, respectively (p < 0.05). In mechanically ventilated patients (n=18), the average CPSV variation expressed as mean + standard deviation before and after fluid administration of 6ml/kg of ideal body weight fluid was 15 ± 5.3 and 6.5 ± 3.1, respectively (p <0.005). Overall, there was a statistically significant positive correlation between LVOT VTI variation and CPSV variation before fluid therapy (correlation coefficient 0.56 and p-value 0.001) and a statistically significant moderate positive correlation post-fluid therapy (correlation coefficient 0.37 and p-value 0.043). Conclusion We found a significant decrease in CPSV variation post-fluid administration in patients who are fluid responders, which mimics a decrease in stroke volume variation after fluid administration in patients who are fluid responsive.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。