Modified carbon paste ion selective electrode for determining Cr(iii) ions in aqueous solutions and some real samples using tetragonal zirconia nanoparticles

采用四方氧化锆纳米粒子改性碳糊离子选择性电极测定水溶液及部分实际样品中的Cr(iii)离子

阅读:1

Abstract

Tetragonal zirconia (t-ZrO(2)) nanoparticles (ionophore) are used in newly designed and improved ion selective electrodes for chromium ion detection as an alternative, low-cost, high-precision, and selectivity method. Tetragonal zirconia nanoparticles were synthesized using a modified co-precipitation technique and calcined at 1000 °C for an hour. The phase composition, surface area, microstructure, pore size and particle size of synthesized t-ZrO(2) nanoparticles were examined using the X-ray diffraction (XRD), Brunauer-Emmett-Teller (BET), transmission electron microscope (TEM) and scanning electron microscopy (SEM) attached with an EDAX unit, respectively. Results from XRD showed that the t-zirconia was synthesized and have nanocrystallites size about 20.2 nm. The nano size of t-ZrO(2) was confirmed by the SEM and TEM (the particle size between 26.48 and 40.4 nm), the mesoporous character (average pore size about 4.868 nm) and large surface area (76.2802 m(2) g(-1)) was confirmed by BET analysis. The paste composition with 67.3 : 30.5 : 2.7 (wt%) graphite, t-ZrO(2), and TCP, respectively, exhibited the best results. With a detection limit of 1.0 × 10(-8) mol L(-1), the electrode displayed a good Nernstian slope of 19.50 ± 0.10 mV decade(-1) over the concentration range from 1.0 × 10(-2) to 1.0 × 10(-8) mol L(-1) of Cr(iii) ions. The built-in sensor displayed a quick response time (7 s), was highly thermally stable in the range of 10 to 60 °C without departing from Nernstian behaviour and could be used for about 60 days in the pH range of 2.0 to 6.0. The electrode demonstrated excellent selectivity for the Cr(iii) ion towards a variety of metal ions. For chromium ion determination, numerous spiked real samples, including honey, water, tea, coffee, milk, cheese, and cosmetics, were used. Validation methods were used, and the results showed that there is no significant difference between the two methods (ICP and ISE) at a 95% confidence level. In several real water samples, the estimated limits of detection, limits of quantification, percent recovery, standard deviation, and relative standard deviation showed the effectiveness of the proposed electrode in the potentiometric detection of Cr(iii) ions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。