Multiphase computed tomography angiography derived from computed tomography perfusion data for the differential diagnosis of intracranial aneurysm and infundibular dilation

利用计算机断层扫描灌注数据进行多期计算机断层扫描血管造影,用于鉴别诊断颅内动脉瘤和漏斗部扩张

阅读:1

Abstract

BACKGROUND: As infundibular dilation (ID) is less likely to cause hemorrhage or other clinical sequelae than an intracranial aneurysm (IA) and treating infundibulum itself may put the patient at unnecessary risk for stroke, it is important to distinguish between the ID and IA. Given the limitations of conventional single-phase computed tomography angiography (sCTA) to show small branches of intracranial arteries, the application of multiphase computed tomography angiography (mCTA) for identification seems promising. Our main objective was to evaluate whether using mCTA derived from computed tomography perfusion (CTP) data can improve distinction between IA and ID. METHODS: A total of 35 patients diagnosed with IA or ID of the posterior communicating artery at its junction with the internal carotid artery junction (ICA-PComA) by sCTA at the 8th Medical Center of Chinese PLA General Hospital between January 2019 and May 2022 were retrospectively selected. All patients underwent CTP. The simulated mCTA was reconstructed from 0.75 mm CTP data for assessment of vascular branches. All data were processed separately by 2 CTA post-processors; 2 observers diagnosed IA and ID by source and volume rendering (VR) images of sCTA and VR images of mCTA, and compared the diagnostic efficacy of source and VR images of sCTA with VR images of mCTA. RESULTS: The quality of the reconstructed images was more consistent between the 2 post-processors mCTA (K=0.856) than sCTA (K=0.648). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the source image for ID identification were 78.9%, 86.7%, 84.2%, 81.3%, and 80.0% for sCTA, 73.7%, 81.2%, 82.3%, 72.2%, and 77.2% for the VR image of sCTA, and 94.7%, 87.5%, 90.0%, 93.3%, and 91.4% for the VR image based on mCTA, respectively. The net reclassification index (NRI) of mCTA for VR and the source image of sCTA was 0.273 and 0.220, respectively. VR base on mCTA was on average better than VR and the source image of sCTA at differentiating ID from IA (P=0.005 and P=0.001, respectively). CONCLUSIONS: Compared to sCTA, mCTA is more helpful in improving the distinction of ID and IA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。