Quality of glycemic control in type 2 diabetes mellitus (T2DM) and its association with markers of coagulation and inhibitors of fibrinolysis: A case-control study in the Upper West Region, Ghana

2型糖尿病(T2DM)血糖控制质量及其与凝血标志物和纤溶抑制剂的关系:加纳上西部地区的一项病例对照研究

阅读:1

Abstract

BACKGROUND AND AIMS: Type 2 diabetes mellitus (T2DM) individuals are at a higher risk of developing diabetes complications, with approximately 80% complication-related mortality. The increased morbidity and mortality among T2DM patients are partly due to dysregulated hemostasis. This study determined the quality of glycemic control in T2DM and its association with markers of coagulation and inhibitors of fibrinolysis. METHODS: This case-control study recruited 90 participants involving: 30 T2DM patients with good glycemic control, 30 with poor glycemic control, and 30 nondiabetic subjects as controls at a Municipal Hospital in Ghana. Fasting blood glucose, glycated hemoglobin, activated partial thromboplastin time (APTT), prothrombin time (PT), calculated international normalized ratio (INR), and full blood count (FBC) were determined for each respondent. Plasma levels of plasminogen activator inhibitor-1 (PAI-1) and thrombin activatable fibrinolysis inhibitor (TAFI) were determined using the solid-phase sandwich enzyme-linked immunosorbent assay method. Data were analyzed using R language software. RESULTS: Plasma PAI-1 antigen levels were significantly higher in the participants with poor glycemic control as compared to participants with good glycemic control (p < 0.0001). There was no significant difference in plasma TAFI levels between the participants with poor glycemic control as compared to participants with good glycemic control (p = 0.900). T2DM patients had significantly shorter APTT, PT, and INR than controls (p < 0.05). At a cut-off of ≥161.70 pg/μL, PAI was independently associated with increasing odds (adjusted odds ratio = 13.71, 95% confidence interval: 3.67-51.26, p < 0.0001) of poor glycemic control and showed the best diagnostic accuracy for poor glycemic control (area under the curve = 0.85, p < 0.0001). CONCLUSION: PAI-1 levels were significantly increased in T2DM with poor glycemic control and emerged as the best predictor for poor glycemic control. Good glycemic management to control the plasma levels of PAI-1 is required to prevent hypercoagulability and thrombotic disorders.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。