Assessment of venous pressure by compression sonography of the internal jugular vein during 3 days of bed rest

卧床休息3天期间,通过颈内静脉加压超声检查评估静脉压

阅读:1

Abstract

Compression sonography has been proposed as a method for non-invasive measurement of venous pressures during spaceflight, but initial reports of venous pressure measured by compression ultrasound conflict with prior reports of invasively measured central venous pressure (CVP). The aim of this study is to determine the agreement of compression sonography of the internal jugular vein (IJVP) with invasive measures of CVP over a range of pressures relevant to microgravity exposure. Ten healthy volunteers (18-55 years, five female) completed two 3-day sessions of supine bed rest to simulate microgravity. IJVP and CVP were measured in the seated position, and in the supine position throughout 3 days of bed rest. The range of CVP recorded was in line with previous reports of CVP during changes in posture on Earth and in microgravity. The correlation between IJVP and CVP was poor when measured during spontaneous breathing (r = 0.29; R(2)  = 0.09; P = 0.0002; standard error of the estimate (SEE) = 3.0 mmHg) or end-expiration CVP (CVP(EE) ; r = 0.19; R(2)  = 0.04; P = 0.121; SEE = 3.0 mmHg). There was a modest correlation between the change in CVP and the change in IJVP for both spontaneous ΔCVP (r = 0.49; R(2)  = 0.24; P < 0.0001) and ΔCVP(EE) (r = 0.58; R(2)  = 0.34; P < 0.0001). Bland-Altman analysis of IJVP revealed a large positive bias compared to spontaneous breathing CVP (3.6 mmHg; SD = 4.0; CV = 85%; P < 0.0001) and CVP(EE) (3.6 mmHg; SD = 4.2; CV = 84%; P < 0.0001). Assessment of absolute IJVP via compression sonography correlated poorly with direct measurements of CVP by invasive catheterization over a range of venous pressures that are physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time. NEW FINDINGS: What is the central question of this study? Compression sonography has been proposed as a novel method for non-invasive measurement of venous pressures during spaceflight. However, the accuracy has not yet been confirmed in the range of CVP experienced by astronauts during spaceflight. What is the main finding and its importance? Our data show that compression sonography of the internal jugular vein correlates poorly with direct measurement of central venous pressures in a range that is physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。