Optimal Protocol and Clinical Usefulness of (123)I-MIBG Cardiac Scintigraphy for Differentiation of Parkinson's Disease and Dementia with Lewy Body from Non-Parkinson's Diseases

(123)I-MIBG心脏闪烁显像在鉴别帕金森病和路易体痴呆与非帕金森病中的最佳方案和临床应用价值

阅读:1

Abstract

PURPOSE: (123)I-metaiodobenzylguanidine (MIBG) cardiac scintigraphy was a useful imaging modality for the diagnosis of Parkinson's disease, but its diagnostic performances were variably reported. This retrospective study compared the diagnostic performances and investigated the optimal imaging protocol of (123)I-MIBG cardiac scintigraphy at various imaging time points in patients suspected of Parkinson's disease in clinical practice. METHODS: In patients suspected of Parkinson's disease, clinical records, autonomic function tests, and (123)I-MIBG cardiac scintigraphy were retrospectively reviewed. Semi-quantitative parameters such as heart-to-mediastinum ratio (HMR) and washout rate (WR) were calculated and compared at 15 min, 1 h, 2 h, 3 h, and 4 h post-injection (p.i.). of (123)I-MIBG cardiac scintigraphy. Group A consisted of Parkinson's disease (PD), Parkinson's disease dementia (PDD), and dementia with Lewy body (DLB), and group B consisted of non-Parkinson's diseases such as multiple system atrophy (MSA), progressive supranuclear palsy (PSP), drug-induced parkinsonism (DIP), essential tremor (ET), Parkinson-plus syndrome (PPS), and unspecified secondary parkinsonism (NA). The diagnostic performances of HMR and WR were compared for differentiation of group A from group B, and their clinical usefulness and optimal imaging time points were explored. RESULTS: Seventy-eight patients were included in group A (67 PD, 7 PDD, 4 DLB), and 18 patients were included in group B (5 MSA, 3 PSP, 2 DIP, 2 ET, 1 PPS, and 1 NA). Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value of HMR and WR were maximized at 4 h p.i., (82.1%, 85.7%, 82.6%, 97.0%, and 46.2%; cutoff threshold < 1.717; area under curve 0.8086) and at the time interval between 1 and 4 h p.i. (65.4%, 85.7%, 68.5%, 96.2%, and 30.8%; cutoff threshold > 24.1%; area under curve 0.8246), respectively, and PPVs of both HMR and WR persistently showed greater than 92.7% at earlier time points and shorter time intervals. CONCLUSION: This study reassured that 4-h-delayed imaging is recommended for the best diagnostic performances in (123)I-MIBG cardiac scintigraphy. Although it showed suboptimal diagnostic performances to differentiate PD, PDD, and DLB from non-Parkinson's diseases, it can be useful as an auxiliary measure for the differential diagnosis in usual clinical practice. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13139-023-00790-w.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。