A network meta-analysis on the efficacy and safety of thermal and nonthermal endovenous ablation treatments

一项关于热消融和非热消融静脉内治疗疗效和安全性的网络荟萃分析

阅读:1

Abstract

OBJECTIVE: We assessed the mid-term efficacy and safety of thermal and nonthermal endovenous ablation for the treatment of lower limb superficial venous insufficiency. METHODS: We performed a systematic review in accordance with the PRISMA (preferred reporting items for systematic reviews and meta-analyses) statement and a Bayesian network meta-analysis. The primary end points were great saphenous vein (GSV) closure and venous clinical severity score (VCSS) improvement. A meta-regression using GSV diameter as a covariate was undertaken for the two primary end points. RESULTS: We included 14 studies and 4177 patients, with a mean follow-up of 25.7 months. Radiofrequency ablation (RFA; odds ratio [OR], 3.99; 95% confidence interval [CI], 1.82-10.53), cyanoacrylate ablation (CAC; OR, 3.09; 95% CI, 1.35-8.37), and endovenous laser ablation (EVLA; OR, 2.72; 95% CI, 1.23-7.38) displayed increased odds for GSV closure compared with mechanochemical ablation (MOCA). MOCA inferiority compared with RFA (mean difference [MD], 0.96; 95% CI, 0.71-1.20), EVLA (MD, 0.94; 95% CI, 0.61-1.24), and CAC (MD, 0.89; 95% CI, 0.65-1.15) was also depicted regarding VCSS improvement. EVLA resulted in an increased risk of postoperative paresthesia compared with MOCA (risk ratio [RR], 9.61; 95% CI, 2.32-62.29), CAC (RR, 7.90; 95% CI, 2.44-38.16), and RFA (RR, 6.96; 95% CI, 2.31-28.04). Although the overall analysis identified nonstatistically significant differences for Aberdeen varicose vein questionnaire score improvement, thrombophlebitis, ecchymosis, and pain, further investigation revealed an increase pain profile for EVLA at 1470 nm compared with RFA (MD, 3.22; 95% CI, 0.93-5.47) and CAC (MD, 3.04; 95% CI, 1.05-4.97). A sensitivity analysis displayed a persistent underperformance of MOCA compared with RFA (OR, 4.33; 95% CI, 1.15-55.54) for GSV closure and both RFA (MD, 0.99; 95% CI, 0.22-1.77) and CAC (MD, 0.84; 95% CI, 0.08-1.65) regarding VCCS improvement. Although no regression model reached statistical significance, the GSV closure regression model revealed a trend for considerably decreased efficacy for both CAC and MOCA with larger GSV diameters compared with RFA and EVLA. CONCLUSIONS: Although our analysis has produced skepticism regarding the efficacy of MOCA in the mid-term period for VCSS improvement and GSV closure rates, CAC showed equivalent results compared with both RFA and EVLA. Additionally, CAC displayed a decreased risk of postprocedural paresthesia and pigmentation and induration compared with EVLA. Also, both RFA and CAC had an improved pain profile compared with EVLA 1470 nm. The potential underperformance of nonthermal, nontumescent ablation modalities in ablating large GSVs necessitates further research.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。