Upper Gastrointestinal Bleeding Secondary to Duodenal Wall Perforation by Inferior Vena Cava Filter: A Rare Clinical Presentation

下腔静脉滤器穿孔导致十二指肠壁穿孔引起的上消化道出血:一种罕见的临床表现

阅读:1

Abstract

Patients with venous thromboembolism (VTE) frequently employ inferior vena cava (IVC) filters to keep them from getting pulmonary embolisms. Even though they are usually thought to be safe, there can be complications during or after their placement. IVC filter perforation into adjacent structures, such as the duodenum, is an uncommon but potentially serious complication. We present a case of a 62-year-old female with a past medical history of recurrent deep vein thrombosis (DVTs) and pulmonary embolism who presented with dizziness and dyspnea due to gastrointestinal (GI) bleeding, resulting in anemia. Esophagogastroduodenoscopy (EGD) was done and revealed a metallic object extending into the duodenum, identified as the IVC filter.