Management of Non-Union Distal Femur Fracture with Augmentation Nail-Plate Construct: A Case Report

采用髓内钉-钢板复合体治疗股骨远端骨折不愈合:病例报告

阅读:1

Abstract

INTRODUCTION: Non-union fractures of the distal femur pose significant challenges in orthopedic surgery, often requiring revision procedures to achieve successful bone healing. In cases where the initial implant has failed, innovative solutions are necessary to promote bone union and functional recovery. CASE REPORT: We present a case of a non-union distal femur fracture in a 22-year-old male patient, with a broken implant in situ. The patient had previously undergone internal fixation with a locking plate, which subsequently failed to promote bone healing. The patient was reoperated using a supracondylar nail and augmented with a distal femur locking plate to address the non-union. The combination of the supracondylar nail and distal femur locking plate successfully provided stability to the fracture site, promoting bone union and enabling functional recovery. Radiographic evidence and clinical assessment demonstrated excellent healing progress. CONCLUSION: This case report highlights the importance of individualized treatment for non-union distal femur fractures, especially when prior implant failure occurs. The combined approach of a supracondylar nail and distal femur locking plate can be a valuable option in addressing complex non-union fractures, achieving stable fixation, and facilitating successful bone healing.