Original Article--Mid-term Clinical and Hemodynamic Outcomes in Middle Age Patients Post Trifecta™ (Abbott) Aortic Valve Replacement: A Single-center Study

原创文章——中年患者接受Trifecta™(雅培)主动脉瓣置换术后的中期临床和血流动力学结果:一项单中心研究

阅读:1

Abstract

BACKGROUND: Trifecta™ is an externally wrapped bovine pericardial aortic valve with a favorable hemodynamic performance and acceptable rate of freedom from structural valve degeneration. However, recent reports of early Trifecta valve failure question its durability. Rheumatic valve disease in young population is predominant, there is no data on the Trifecta performance, durability or safety available worldwide over the middle age population, as well as there are no previous similar reports from Middle East region. We report on mid-term clinical and hemodynamic performance of Trifecta valve in middle age population with small aortic annuls, a single center report. METHODS: A retrospective study of all patients who underwent Trifecta™ SAVR between June 2014 and December 2019 at a cardiac center in Riyadh, Saudi Arabia. Hemodynamic performance was analyzed by longitudinal Doppler echocardiography. RESULTS: During a 5.5-year period, a total of 24 patients underwent SAVR with Trifecta™ valves at our heart center. Patients had a median age of 47.1 years (IQR = 37) and male:female ratio of 1:1. Patients had a median EuroScoreII of 2 (IQR = 1). The 19 mm valve was the most frequently used (29.2%) followed by the 21 mm and 23 mm (both 25.0%). Concomitant procedure was (54.2%). All patients survived their operations and most (87.0%) had their symptoms relieved. A 30-day mortality rate of 4.2%. Patients were followed up for a median of 58.5 months (IQR = 38), during which 8.3% required re interventions, giving an overall freedom from re-intervention of 91.7%. The re-intervention after valve implantation was recorded in two (8.3%). These re-interventions were performed 3 years post initial surgery and were due to structural valve deterioration (SVD). The mean gradient reduced significantly from 43.6 ± 23.9 mmHg (median = 41, IQR = 21) at baseline to 13.0 ± 7.4 mmHg (median = 11, IQR = 5) one-week post intervention (p < 0.001). The average mean gradients were stable from post-operation to follow-up (13.0 ± 7.4 vs 14.1 ± 6.4 mmHg). CONCLUSION: Our study confirms excellent mid-term durability, clinical and hemodynamic performance of the Trifecta™ valve in middle age population, despite the fact of non-statically significant trend-up of transvalvular gradient over the follow up period. Further long-term studies with larger sample-size are warranted to confirm these results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。