Comparison of dynamic hip screw with anti-rotation screw and femoral neck system internal fixation for the treatment of garden II-IV type femoral neck fractures

动态髋螺钉与防旋转螺钉和股骨颈系统内固定治疗Garden II-IV型股骨颈骨折的比较

阅读:1

Abstract

BACKGROUND: Femoral neck fractures, which are fractures occurring from the femoral head to the base of the femoral neck, are prevalent in the elderly population. With the progression of societal aging, the incidence of femoral neck fractures has been steadily increasing, making it a significant global issue that urgently needs to be addressed. OBJECTIVE: To compare the efficacy and safety of dynamic hip screw (DHS) with anti-rotation screw and femoral neck system (FNS) internal fixation for the treatment of Garden II-IV type femoral neck fractures. METHODS: A total of 90 patients with Garden II-IV type femoral neck fractures were randomly assigned to either the control group (n= 45) treated with DHS and anti-rotation screw or the experimental group (n= 45) treated with FNS. Surgical outcomes, including incision size, blood loss, operation time, fluoroscopy frequency, and fracture healing time, were compared. Postoperative complication rates, reoperation rates, Harris scores, and visual analogue scale (VAS) scores were also assessed. RESULTS: The experimental group demonstrated significantly reduced incision length, blood loss, operation time, and fluoroscopy frequency compared to the control group (P< 0.01). No significant differences were observed in fracture healing time, Garden classification, or fracture reduction outcomes between the two groups (P> 0.05). At 6 months post-treatment, both groups showed significant improvements in Harris scores and VAS scores compared to pre-treatment (P< 0.05), with no significant differences between the groups (P> 0.05). The rates of internal fixation failure, nonunion, and avascular necrosis of the femoral head, as well as overall incidence of postoperative complications and reoperation rates, showed no significant differences between the two groups (P> 0.05). CONCLUSIONS: Both DHS with anti-rotation screw and FNS internal fixation demonstrated comparable efficacy and safety profiles in the treatment of Garden II-IV type femoral neck fractures. The experimental group showed advantages in terms of reduced incision length, blood loss, operation time, and fluoroscopy frequency, while maintaining similar clinical outcomes and complication rates.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。