Comparative Evaluation of Mechanical Properties and Microleakage of Cention N and Titanium Dioxide Nanoparticles-Enriched Cention N: An In Vitro Study

Cention N 和富含二氧化钛纳米颗粒的 Cention N 的力学性能和微渗漏性能的比较评价:一项体外研究

阅读:1

Abstract

Aim This study aimed to assess and compare the mechanical properties, including compressive strength, diametral tensile strength, flexural strength, fracture resistance, microhardness, and microleakage, between Cention N (Ivoclar Vivadent, Gurugram, India) and Cention N enriched with titanium dioxide (TiO(2)) nanoparticles. Methodology A total of 120 samples were involved in the study, which were split into two experimental groups. For evaluation of each mechanical property, 20 samples were included, of which 10 samples were used for evaluating the properties of Cention N and 10 samples were used for TiO(2 )nanoparticles-enriched Cention N. Samples, formed using Teflon molds, were filled with Cention N and TiO(2)-enriched Cention N powders mixed per the manufacturer's instructions. The universal testing machine (UTM) was used to assess compressive, flexural, diametral tensile strength, and fracture resistance. Microhardness was evaluated using a diamond indenter, while microleakage was examined utilizing a stereomicroscope. Results The nanotitania-enriched Cention N showed significantly increased mechanical properties and increased microhardness with the least microleakage. Conclusion The inclusion of TiO(2) in Cention N has proved to yield promising results.