Clinical outcome of rim-plate-augmented separate vertical wiring with supplementary fixation for the treatment of patellar fracture associated comminuted inferior pole

采用边缘钢板加固的独立垂直钢丝固定联合辅助内固定治疗髌骨骨折合并粉碎性下极骨折的临床疗效

阅读:1

Abstract

Despite the variety of treatment methods, comminuted inferior pole fractures of the patella remain difficult and technically demanding to achieve stable internal fixation. The purpose of this study is to evaluate the clinical outcomes of rim plate-augmented separate vertical wiring with supplementary fixation in the management of comminuted inferior pole fractures, AO/OTA 34-A1, C2, and C3, which has the secondary horizontal fracture line on lower articular boundary. From our study, bony union was achieved in all patients at an average of 3.1 ± 1.4 months after surgery. There was no patient with loss of reduction, fixation failure, or infection during follow-up. The average final range of motion was 131.6° ± 7.2°. Lysholm knee scores gradually increased over 3, 6, 9, and 12 months postoperatively by 58.7, 74.0, 82.9, and 89.4, respectively. Isokinetic peak torque deficit of the knee extensor muscles in 3, 6, 9, and 12 months postoperatively was 59.9%, 49.7%, 35.7%, and 28.1%, respectively. The rim plate-augmented separate vertical wiring with supplementary fixation for the treatment of patellar fracture associated comminuted inferior pole is effective and can be safely applied AO/OTA 34-C2 or C3 with favorable outcomes.