An in vivo study to assess and compare the angular, linear, and depth deviation as well as the difference in bone density of implants placed using computer-aided design/computer-aided manufacturing fabricated three-dimensional guides versus the implants placed using bone pen kit in maxillary and mandibular ridges

一项体内研究旨在评估和比较使用计算机辅助设计/计算机辅助制造的三维导板植入的种植体与使用骨笔工具包植入的种植体在上颌和下颌牙槽嵴中的角度、线性和深度偏差以及骨密度差异。

阅读:1

Abstract

AIM: The aim is to assess and compare angular, linear, and depth deviation and difference in bone density of dental implants placed using computer aided design/computer aided manufacturing (CAD/CAM) fabricated surgical guides versus implants placed using Bone Pen Kit. Till now, no original research exists in the search engines such as Pubmed, Google Scholar, Science Direct, and Research Gate on this kit. SETTINGS AND DESIGN: In vivo- Randomised control trial. MATERIALS AND METHODS: Twenty clinical cases were selected and split into two distinct groups. Group 1 involved the placement of 10 implants using CAD/CAM fabricated three dimensional guides and Group 2 involved the placement of 10 implants using Bone Pen Kit. Four deviation parameters were evaluated, which included: (a) Angular deviation, (b) Linear deviation at implant platform, (c) Linear deviation at implant apex, and (d) Depth deviation and difference in bone density before and after implant placement was also evaluated. STATISTICAL ANALYSIS USED: SPSS software version 23 was utilized for the analysis of the data. The comparison was made using the Whitney test, and Wilcoxon signed rank test. RESULTS: When comparing angular deviation, the results indicated a statistically significant difference with a P < 0.05. The values observed for angular and linear deviation in Group 2 were significantly greater than those in Group 1. No statistically significant difference in depth and linear deviation was found at the implant platform among the two groups. Bone density before and after implant placement was significantly higher in Group 1. CONCLUSIONS: (1) Angular and linear deviation at the apex in Group 2 exhibited higher values in comparison to Group 1, (2) No difference in depth and linear deviation at the implant platform was found among the two groups, and (3) There was no difference in change in bone density among two groups.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。