Initial clinical experience with the novel POLARx FIT cryoballoon system for pulmonary vein isolation in patients with atrial fibrillation

新型POLARx FIT冷冻球囊系统在房颤患者肺静脉隔离术中的初步临床经验

阅读:1

Abstract

BACKGROUND: The POLARx FIT system (Boston Scientific, MA, USA) is a novel cryoballoon (CB) ablation technology in which the balloon diameter can be expanded from 28 to 31 mm. The aim of this study was to compare the benefits and safety of the new POLARx FIT system to those of the existing POLARx system currently in use for pulmonary vein (PV) isolation (PVI) in patients with atrial fibrillation. METHODS: The first 70 consecutive patients who underwent CB-based PVI with the POLARx FIT system were retrospectively compared with 200 consecutive patients treated with the POLARx system at Sakakibara Heart Institute from October 2021 to May 2023. RESULTS: The POLARx FIT system yielded a higher mean ± standard deviation nadir temperature in the right inferior PV (-59.2 ± 5.29 °C vs. - 62.0 ± 5.08 °C, p = 0.006), but this required a balloon size reduction to 28 mm in 30 % of cases. No significant differences were detected in the time to isolation and thaw time of any PV between the two groups. After the CB-based PVI procedure, no residual PV carina potentials were observed with the POLARx FIT system, whereas 4/20 were with the POLARx system (p = 0.04). CONCLUSIONS: The POLARx FIT system had comparable effectiveness and safety to the basic POLARx system. This technology may improve the ablation area, including the PV carina. However, the 31-mm balloon alone was not sufficient to isolate certain PVs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。