Primary Cooperative Application of a LARS® Tube and 3D-Printed Prosthesis for Reconstruction of the Distal Radius after en bloc Resection of Giant Cell Tumor of Bone: A Comparative Retrospective Study

巨细胞瘤整块切除后远端桡骨重建中LARS®管和3D打印假体的初步联合应用:一项比较性回顾性研究

阅读:1

Abstract

OBJECTIVE: Using a fibula autograft (FA) to reconstruct defects after en bloc resection of giant cell tumor of bone (GCTB) in the distal radius is classic but has high complication rates. We describe a novel reconstruction method employing the cooperative application of LARS® and a 3D-printed prosthesis (L-P) and investigate whether it improves postoperative outcomes. METHODS: From April 2015 to August 2022, 14 patients who underwent the cooperative L-P reconstruction method after en bloc resection of distal radial GCTBs and 31 patients who received FA reconstruction were enrolled as two retrospective cohorts in this comparative study. The properties of the implants and critical surgical techniques were elaborated in the L-P group. Preoperative function, intraoperative data, and postoperative clinical, functional, and radiographic outcomes of all patients were recorded and compared between the two groups. The grip strength and range of wrist motion, including extension, flexion, radial deviation, and ulnar deviation, were measured. The Mayo modified wrist and Musculoskeletal Tumor Society scores were chosen to assess wrist function and surgical functional outcomes, respectively. Kaplan-Meier curves were generated to analyze the significant differences in complication rates and implant survival between the two groups. RESULTS: In both groups, all 45 patients underwent the operation without complication with similar average osteotomy lengths and bleeding volumes, while a shorter operative duration was achieved in the L-P group (201.43 ± 22.87 min vs. 230.16 ± 51.44 min, P = 0.015). At a mean follow-up of 40.42 ± 18.43 months (range, 14-72 months), both reconstruction methods effectively ameliorated postoperative function. Patients who received L-P showed higher postoperative modified Mayo wrist scores (81.43 ± 5.49 vs. 71.13 ± 16.10, P = 0.003), Musculoskeletal Tumor Society scores (27.64 ± 1.34 vs. 25.06 ± 2.95, P = 0.004), and grip strength on the normal side (68.71% ± 8.00% vs. 57.81% ± 12.31%, P = 0.005) than the FA group. Better wrist extension (63.21° ± 8.99° vs. 45.32° ± 14.53°, P < 0.001) and flexion (45.36° ± 7.90° vs. 30.48° ± 12.07°, P < 0.001) were also observed in the L-P group. The complication rate was significantly higher in the FA group (29/31, 93.55%) than in the L-P group (1/14 7.14%, P < 0.001). The L-P group showed higher implant survival than the FA group, but the difference was not statistically significant. CONCLUSION: The cooperative application of LARS® and 3D-printed prostheses is an effective modality for reconstructing musculoskeletal defects after en bloc resection of distal radial GCTBs, which can improve functional outcomes, diminish complication rates, and promote wrist joint stability and motion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。