Dynamic relative regional lung strain estimated by computed tomography and electrical impedance tomography in ARDS patients

ARDS患者动态相对区域肺应变的计算机断层扫描和电阻抗断层扫描评估

阅读:1

Abstract

BACKGROUND: In the acute distress respiratory syndrome (ARDS), specific lung regions can be exposed to excessive strain due to heterogeneous disease, gravity-dependent lung collapse and injurious mechanical ventilation. Computed tomography (CT) is the gold standard for regional strain assessment. An alternative tool could be the electrical impedance tomography (EIT). We aimed to determine whether EIT-based methods can predict the dynamic relative regional strain (DRRS) between two levels of end-expiratory pressure (PEEP) in gravity-non-dependent and dependent lung regions. METHODS: Fourteen ARDS patients underwent CT and EIT acquisitions (at end-inspiratory and end-expiratory) at two levels of PEEP: a low-PEEP based on ARDS-net strategy and a high-PEEP titrated according to EIT. Three EIT-based methods for DRRS were compared to relative CT-based strain: (1) the change of the ratio between EIT ventilation and end-expiratory lung impedance in arbitrary units ([ΔZ(AU low-PEEP)/EELI(AU low-PEEP)]/[ΔZ(AU high-PEEP)/EELI(AU high-PEEP)]), (2) the change of ΔZ/EELI ratio calibrated to mL ([ΔZ(ml low-PEEP)/EELI(ml low-PEEP)]/[ΔZ(ml high-PEEP)/EELI(ml high-PEEP)]) using CT data, and (3) the relative change of ∆Z(AU) (∆Z(AU low-PEEP)/∆Z(AU high-PEEP)). We performed linear regressions analysis and calculated bias and limits of agreement to assess the performance of DRRS by EIT in comparison with CT. RESULTS: The DRRS assessed by (ΔZ(ml low-PEEP)/EELI(ml low-PEEP))/(ΔZ(ml high-PEEP)/EELI(ml high-PEEP)) and ∆Z(AU low-PEEP)/∆Z(AU high-PEEP) showed good relationship and agreement with the CT method (R(2) of 0.9050 and 0.8679, respectively, in non-dependent region; R(2) of 0.8373 and 0.6588, respectively, in dependent region; biases ranging from - 0.11 to 0.51 and limits of agreement ranging from - 0.73 to 1.16 for both methods and lung regions). Conversely, DRRS based on EELI(AU) ([ΔZ(AU low-PEEP)/EELI(AU low-PEEP)]/[ΔZ(AU high-PEEP)/EELI(AU high-PEEP)]) exhibited a weak negative relationship and poor agreement with the CT method for both non-dependent and dependent regions (R(2) ~ 0.3; bias of 3.11 and 2.08, and limits of agreement of - 2.13 to 8.34 and from - 1.49 to 5.64, respectively). CONCLUSION: Changes in DRRS during a PEEP trial in ARDS patients could be monitored using EIT, based on changes in ΔZ(mL)/EELI(ml) and ∆Z(AU). The relative change ∆Z(AU) offers the advantage of not requiring CT data for calibration.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。