Toward Single-Time-Point Image-Based Dosimetry of (177)Lu-PSMA-617 Therapy

迈向基于单时间点图像的(177)Lu-PSMA-617治疗剂量测定

阅读:1

Abstract

Radiopharmaceutical therapies (RPTs) with (177)Lu-prostate-specific membrane antigen (PSMA) ligands have demonstrated promising results for the treatment of metastatic castration-resistant prostate cancer. The lack of absorbed-dose-effect relationships currently prevents patient-specific activity personalization. To ease the implementation of dosimetry in the routine clinical workflow for RPT, simplified methods such as single-time-point (STP) instead of multiple-time-point (MTP) imaging protocols are required. This work aimed at assessing differences in the time-integrated activity (TIA) of STP versus MTP image-based dosimetry for (177)Lu-PSMA-617 therapy. Methods: Twenty metastatic castration-resistant prostate cancer patients with MTP quantitative (177)Lu-SPECT imaging data (∼24, 48, and 72 h post injection (p.i.)) available on first and second (177)Lu-PSMA-617 therapy cycles were included in this study. Time-activity curves were fitted for kidneys and lesions to derive effective half-lives and yield a reference TIA. STP approaches involved the formula by Hänscheid (STP(H)) and a prior-information method (STP(prior)) that uses the effective half-lives from the first therapy cycle. All time points were considered for the STP approaches. Percentage differences (PDs) in TIA between STP and MTP were compared for the second therapy cycle. Results: Using STP(H) at 48 h p.i. for kidneys showed a -1.3% ± 5.6% PD from MTP, whereas STP(prior) showed a PD of 4.6% ± 6.2%. The smallest average PDs for the 56 investigated individual lesions were found using STP(prior) at 48 h p.i., at only 0.4% ± 14.9%, whereas STP(H) at 72 h p.i. had a smallest PD of -1.9% ± 14.8%. Conclusion: STP dosimetry for (177)Lu-PSMA-617 therapy using a single SPECT/CT scan at 48 or 72 h p.i. is feasible, with a PD of less than ±20% compared with MTP. The validity of both STP(H) and STP(prior) has been demonstrated. We believe this finding can increase the adoption of dosimetry and facilitate implementation in routine clinical RPT workflows. Doing so will ultimately enable the finding of dose-effect relationships based on fixed therapy activities that may, in future, allow for absorbed-dose-based RPT activity personalization.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。