Dosimetric comparison between stereotactic body radiotherapy and carbon-ion radiation therapy for prostate cancer

前列腺癌立体定向放射治疗与碳离子放射治疗的剂量学比较

阅读:1

Abstract

BACKGROUND: Prostate cancer rates have been steadily increasing in recent years. As high-precision radiation therapy methods, stereotactic body radiation therapy (SBRT) and carbon-ion radiation therapy (CIRT) have unique advantages. Analyzing the dosimetric differences between SBRT and CIRT in the treatment of localized prostate cancer can help provide patients with more accurate, individualized treatment plans. METHODS: We selected computed tomography positioning images and the contours of target volumes of 16 patients with localized prostate cancer who received radiotherapy. We delineated the organs at risk (OARs) on the CyberKnife (CK) treatment planning system (TPS) MultiPlan4.0, which were imported into the CIRT uniform scanning TPS HIMM-1 ci-Plan. Two treatment plans, SBRT and CIRT, were designed for the same patient, and we used SPSS 22.0 for the statistical analysis of data. RESULTS: Both SBRT and CIRT plans met the prescribed dose requirements. In terms of target volume exposure dose, D2 (P<0.001), D5 (P<0.001), D50 (P<0.001), D90 (P=0.029), D95 (P<0.001), D98 (P<0.001), and D(mean) (P<0.001) under SBRT were significantly higher than those under CIRT; the conformity index (CI) under SBRT was significantly better than that under CIRT (P<0.001); the target volume coverage rate (V95%) and dose homogeneity index (HI) under CIRT were significantly better than those under SBRT (P<0.001). In terms of OAR exposure dosage, the D(max) of the bladder and rectum under SBRT was significantly lower than that under CIRT (P<0.001), but D(mean) was in the other direction; the exposure dose of the intestinal tract under CIRT was significantly lower than that under SBRT (P<0.05); D(max) of the femoral head under CIRT was significantly lower than that under SBRT (P<0.05), and there was no statistical difference between them at other doses. CONCLUSIONS: In this study, we found that when CIRT was used for treating localized prostate cancer, the dose distribution in target volume was more homogeneous and the coverage rate was higher; the average dose of OARs was lower. SBRT had a better CI and higher dose in target volume; the dose hotspot was lower in OARs. It is important to comprehensively consider the dose relationship between local tumor and surrounding tissues when selecting treatment plans.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。