Management of Distal Femur Unicondylar Fractures by Calcaneal Buttress Plating: A Prospective Interventional Study

采用跟骨支撑钢板治疗股骨远端单髁骨折:一项前瞻性干预研究

阅读:1

Abstract

BACKGROUND: Unicondylar fracture of distal femur accounts for less than 1% of all femoral fractures. As conservative methods have shown substandard results, traditional surgical treatment includes open reduction and internal fixation by Herbert screws, cannulated screws, and conventional lateral locking plates. Though screw fixation has excellent results over long run, there is literature documenting the loosening and loss of articular congruency in elderly patients and in comminuted fracture patterns. Also, the traditional locking plates are precontoured to fit the lateral condyle, whereas there is no specific implant to fix the medial condylar fractures. The merit of the calcaneal plating is that it is easily moldable and can be used for either of the sides irrespective of fracture pattern. OBJECTIVES: This study aimed to evaluate the clinical outcome of calcaneal plate (D-shape) fixation in distal femur unicondylar fractures. MATERIALS AND METHODS: A total of 30 patients were studied, who met the inclusion criteria and consented to the surgery. After appropriate investigations, these patients were treated with calcaneal plating and were followed up postoperatively at 2 weeks, 1 month, 3 months, and 6 months for clinical evaluation. RESULTS: There was a gradual increase in the range of motion (ROM) with subsequent follow-ups. The overall mean ROM evaluated at 6 months was 108.46° ± 28.27° with P < 0.001 and was a statistically significant outcome. Also, the mean ROM for sagittal split fractures (~120°) was comparatively more than the coronally split fractures (~90°). The functional outcome assessed by Neer scoring showed excellent and satisfactory results in 24 (80%) patients, whereas the remaining six (20%) patients had poor results. None of the patients had nonunion, infection, or implant failure. CONCLUSION: With no specific implant for isolated unicondylar fractures, the use of calcaneal plate in our study has shown promising results probably due to its low profile design reducing the soft-tissue irritation and wide area of bone coverage by the plate offering regions of intermittent fixation due to its spanning design, thereby promoting periosteal preservation and ultimately fracture union.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。