Interspinous-Interbody Fusion via a Strictly Lateral Surgical Approach: A Biomechanical Stabilization Comparison to Constructs Requiring Both Lateral and Posterior Approaches

仅采用侧方入路行棘突间椎体间融合术:与需要侧方和后方入路的手术方式的生物力学稳定性比较

阅读:1

Abstract

Objective Lumbar fusion performed through lateral approaches is becoming more common. The interbody devices are generally supported by supplemental posterior fixation implanted through a posterior approach, potentially requiring a second incision and intraoperative repositioning of the patient. A minimally invasive lateral interspinous fixation device may eliminate the need for intraoperative repositioning and avoid disruption of the supraspinous ligament. The objective of this in vitrobiomechanical study was to investigate segmental multidirectional stability and maintenance of foraminal distraction of a lateral interspinous fixation device compared to commonly used pedicle screw and facet screw posterior fixation constructs when combined with lumbar interbody cages. Methods Six human cadaver lumbar spine specimens were subjected to nondestructive quasistatic loading in the following states: (1) intact; (2) interspinous fixation device alone and (3) with lateral interbody cage; (4) lateral lumbar interbody cage with bilateral pedicle screws; (5) lateral lumbar interbody cage with unilateral pedicle screws; and (6) lateral lumbar interbody cage with facet screws. Multidirectional pure bending in 1.5 Nm increments to 7.5 Nm, and 7.5 Nm flexion-extension bending with a 700 N compressive follower load were performed separately with optoelectronic segmental motion measurement. Relative angular motions of L2-L3, L3-L4, and L4-L5 functional spinal units were evaluated, and the mean instantaneous axis of rotation in the sagittal plane was calculated for the index level. Foraminal height was assessed during combined flexion-extension and compression loading for each test construct. Results All implant configurations significantly restricted flexion-extension motion compared with intact (p < 0.05). No significant differences were found in flexion-extension when comparing the different posterior implants combined with lateral lumbar interbody cages. All posterior fixation devices provided comparable neuroforaminal distraction and maintained distraction during flexion and extension. Conclusions When combinedwith lateral lumbar interbody cages, the minimally invasive lateral interspinous fixation device effectively stabilized the spine and maintained neuroforaminal distraction comparable to pedicle screw constructs or facet screws. These results suggest the lateral interspinous fixation device may provide a favorable alternative to other posterior systems that require patient repositioning during surgery and involve a greater disruption of native tissues.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。