A Novel Method to Accelerate Orthodontic Tooth Movement Using Low-Intensity Direct Electrical Current in Patients Requiring en-Masse Retraction of the Upper Anterior Teeth: A Preliminary Clinical Report

一种利用低强度直流电加速正畸牙齿移动的新方法,用于需要整体内收上前牙的患者:初步临床报告

阅读:1

Abstract

BACKGROUND: Shortening the duration of orthodontic treatment by speeding up the rate of tooth movement has become an essential goal for both orthodontists and patients. This preliminary report aimed to investigate the safety and effectiveness of a new intraoral removable electrical device in accelerating the en-masse retraction of the upper anterior teeth using low-intensity direct electrical current. METHODS: This prospective preliminary interventional clinical study was conducted at the Department of Orthodontics, Faculty of Dentistry, Damascus University, Syria, between March 2019 and February 2020. The sample consisted of six patients (four females and two males; mean age: 19.55 ± 0.89 years) whose initial diagnosis was class II division I malocclusion, and their treatment plan suggested the extraction of upper first premolars followed by en-masse retraction. The electrical stimulation was applied on the maxillary anterior region during the en-masse retraction phase using a specially fabricated removable device that was designed by two coauthors of this manuscript (RIS, MYH). Patients were asked to wear their own electrical devices inside their mouths for five hours daily. The primary outcomes were the en-masse retraction rate and duration. The secondary outcomes were safety and patient acceptance. RESULTS: The average total retraction rate during the treatment period was 0.97±0.06 mm/month. The total amount of retraction achieved during follow-up was 5.65 ± 0.85 mm, which was about 91.86% of the space resulting from the extraction of the upper first premolars. The mean treatment duration to complete the en-masse retraction was 5.66±0.81 months. No side effects of the electrical stimulation were found during the follow-up. CONCLUSIONS: Low-intensity direct electrical current could be an effective method to accelerate orthodontic movement. The electrical accelerating device used in this study effectively increased the en-masse retraction rate of the upper anterior teeth without any side effects and with high patient acceptance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。