Could radiological parameters help to predict the failure of ureteral access sheath placement

放射学参数能否帮助预测输尿管鞘置入失败

阅读:1

Abstract

To identify the radiological parameters which may help to predict the success of ureteral access sheath (UAS) placement during retrograde intrarenal surgery (RIRS).The study included 49 patients in whom failure ureteral access sheath placement in RIRS and 49 control group patients who were successfully placement between January 2023 and December 2023. The age, gender, body mass index (BMI), non-contrast computed tomography (NCCT), and kidney ureter bladder (KUB) radiographs were compared between the two groups. Measurements of the anteroposterior (ap) diameter of the pelvic inlet, anteroposterior diameter of the pelvic outlet, interspinous distance diameter were taken from non-contrast computed tomography (NCCT), while pelvic anteroposterior diameter and pelvic lateral diameter were measured from kidney ureter bladder (KUB) radiography. There were no significant differences between the groups in age, gender, body mass index, ap pelvic inlet diameter, ap pelvic outlet, and interspinous distance diameter. However, a statistically significant difference was found between the pelvic ap diameter and pelvic lateral diameter values measured on the KUB radiography. The values for pelvic ap diameter and pelvic lateral diameter measured in the KUB radiographs can be used to predict the likelihood of UAS passage during RIRC procedures. However, further studies with larger patient groups are needed to establish a cut-off value.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。