Optimizing Acute Stroke Segmentation on MRI Using Deep Learning: Self-Configuring Neural Networks Provide High Performance Using Only DWI Sequences

利用深度学习优化MRI急性卒中分割:自配置神经网络仅使用DWI序列即可实现高性能分割

阅读:1

Abstract

Segmentation of infarcts is clinically important in ischemic stroke management and prognostication. It is unclear what role the combination of DWI, ADC, and FLAIR MRI sequences provide for deep learning in infarct segmentation. Recent technologies in model self-configuration have promised greater performance and generalizability through automated optimization. We assessed the utility of DWI, ADC, and FLAIR sequences on ischemic stroke segmentation, compared self-configuring nnU-Net models to conventional U-Net models without manual optimization, and evaluated the generalizability of results on an external clinical dataset. 3D self-configuring nnU-Net models and standard 3D U-Net models with MONAI were trained on 200 infarcts using DWI, ADC, and FLAIR sequences separately and in all combinations. Segmentation results were compared between models using paired t-test comparison on a hold-out test set of 50 cases. The highest performing model was externally validated on a clinical dataset of 50 MRIs. nnU-Net with DWI sequences attained a Dice score of 0.810 ± 0.155. There was no statistically significant difference when DWI sequences were supplemented with ADC and FLAIR images (Dice score of 0.813 ± 0.150; p = 0.15). nnU-Net models significantly outperformed standard U-Net models for all sequence combinations (p < 0.001). On the external dataset, Dice scores measured 0.704 ± 0.199 for positive cases with false positives with intracranial hemorrhage. Highly optimized neural networks such as nnU-Net provide excellent stroke segmentation even when only provided DWI images, without significant improvement from other sequences. This differs from-and significantly outperforms-standard U-Net architectures. Results translated well to the external clinical environment and provide the groundwork for optimized acute stroke segmentation on MRI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。