Personalized Guidance of Edge-to-Edge Transcatheter Tricuspid Valve Repair by Multimodality Imaging

多模态影像指导经导管三尖瓣缘对缘修复术的个性化应用

阅读:1

Abstract

Background: Transcatheter edge-to-edge tricuspid valve repair (T-TEER) for tricuspid regurgitation (TR) is always guided by transesophageal echocardiography (TEE). As each patient has unique anatomy and acoustic window, adding transthoracic echocardiography (TTE) and cardiac CT could improve procedural planning and guidance. Objectives: We aimed to assess T-TEER success and outcomes of a personalized guidance approach, based on multimodality imaging (MMI) of patient-tailored four right-sided chamber views (four-right-ch), as depicted by CT, TTE, TEE and fluoroscopy. Methods: Patients were assigned to MMI or classical TEE guidance, depending on TTE acoustic window. In MMI patients, planning included cardiac CT, which determined the fluoroscopic angulations of the specific four-right-ch, while guidance relied heavily on TTE, with minimal intermittent TEE for leaflet grasping and result confirmation. Both TTE and TEE were matched to respective CT and fluoroscopy four-right-ch. TR severity and quality of life (QoL) parameters were assessed from baseline to 12 months. Results: A total of 40 T-TEER patients were included, with 17 procedures guided by MMI and 23 solely by TEE. Baseline characteristics were similar between groups, e.g., age (83.1 ± 4.1 vs. 81 ± 5.3, p = 0.182) or STS-Score (11.1 ± 7.4% vs. 10.6 ± 5.9%, p = 0.813). The primary efficacy endpoint of ≥one-grade TR reduction at 30 days was 94% (16/17) in MMI vs. 91% (21/23) in TEE patients, with two or more TR grade reduction in 65% vs. 52% (p = 0.793). Device success was overall 100%, with no device-related complications, but three TEE-associated cases of gastrointestinal bleeding in the TEE-only group. By 12 months, all 15 MMI and 19 TEE survivors improved NYHA functional class and QoL, e.g., Kansas City Cardiomyopathy Questionnaire Score Δ29.6 ± 6.7 vs. 21.9 ± 5.8 (p = 0.441) pts., 6-min walk distance Δ101.5 ± 36.4 vs. 85.7 ± 32.1 (p = 0.541) meters. Conclusions: In a subset of patients with good TTE acoustic window, MMI guidance of T-TEER is effective and seems to avoid gastroesophageal injuries caused by TEE probe manipulation. TR reduction, irrespective of guidance method, impacts long-term QoL.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。